      387,476, 487,490系列Hawke防爆变径,防爆堵头,防爆呼吸阀等价格及库存

EPIN原装进口Hawke防爆格兰,Hawke防爆堵头,Hawke防爆变径接头,Hawke防爆电控箱等,广泛应用于石油石化和海洋钻井平台,有ATEX认证和ABS等认证。

387,476, 487,490系列Hawke防爆堵头价格及库存

EPIN原装进口Hawke防爆格兰,Hawke防爆堵头,Hawke防爆变径接头,Hawke防爆电控箱等,广泛应用于石油石化和海洋钻井平台,有ATEX认证和ABS等认证。

Hawke487 Domed Head Stopping Plug

Flameproof Exd / Increased Safety Exe / Dual Certified ATEX - IECEx

General Information

M16 to M130 as standard.
Other parallel thread options available on request, including BSPP, PG, NPSM and ET. NPT available as 387 Exe Plug.
Metric entry threads are 1.5mm pitch as standard.

Materials & Finishes

Manufactured in Brass, Nickel Plated Brass, Steel, Nickel Plated Steel and Stainless Steel. (Aluminium for Group II use only).

Technical Data

  1. Increased Safety and Flameproof Exe I Mb, Exd I Mb, Exe IIC Gb, Exd IIC Gb, Extb IIIC Db, ex logo IM2 / II 2GD.
  2. Certificate Nos
    baseefa11ATEX0149X and IECEx BAS 11.0071X.
  3. Suitable for use in:
    Zone 1, Zone 2, Zone 21, Zone 22 and mining applications.
  4. Construction and Test Standards:
    IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31.
  5. Ingress Protection:
    IP66.
  6. Operating Temperature Range:
    Nitrile ‘O’ Ring fitted as standard -60°C to 80°C.
    Silicone Option -60°C to 160°C.
  7. Group I, II and III.
487 STOPPING PLUGS SELECtION TABLE
Thread Size Length of Thread ‘S’ Dia. Allen Key
M16 15 24 6
M20 15 26.5 10
M25 15 34 10
M32 15 45 10
M40 15 51.5 10
M50 15 61.5 10
M63 15 74.5 10
M75 15 86.5 10
All dimensions in millimetres.

Ordering Format [ Product / Thread Size / Material / Finish ]

Example: 487 / M32 / Brass / Nickel Plated

Hawke387 Domed Head Stopping Plug

Increased Safety Exe / Dual Certified ATEX - IECEx

Application

To close unused cable gland entries and maintain the integrity of the equipment.

Materials & Finishes

387 Stopping Plugs are manufactured in Brass (standard), Nickel Plated Brass or 316 Stainless Steel..

Ordering Format [ Product / Thread Size ]

Example: 387 / ½" NPT

Technical Data

  1. Increased Safety Exe ex logo II 2 GD IP66
  2. Certificate Nos
    baseefa06ATEX0118U and IECEx BAS06.0029U
  3. Construction and Test Standards:
    IEC/EN 60079-0 and IEC/EN 60079-7.
  4. Ingress Protection:
    To meet with IP66 and IP67, the stopping plugs must be fitted perpendicular to the equipment face in a suitably sized threaded or plain hole and the equipment face must be smooth. Plain holes must be no larger than 0.7mm above the major diameter of the stopping plug thread and the plug must be held in place with a lock nut. A serrated washer may also be fitted.
  5. Operating Temperature Range:
    Nitrile ‘O’ Ring fitted as standard -60°C to 80°C.
    Silicone Option -60°C to 160°C.
387 STOPPING PLUG SELECTION TABLE
Thread Size * ‘S’ Dia. Key Size (Across Flats)
½" NPT 30.0 8.0
¾" NPT 36.5 10.0
1" NPT 44.0 10.0
1¼" NPT 56.0 10.0
1½" NPT 62.0 19.0
2" NPT 74.5 19.0
2½" NPT 87.2 19.0
3" NPT 104.0 19.0
All dimensions in millimetres (except * where dimensions are in inches).

Hawke479 Inline Adaptor (Male to Male)

Flameproof Exd / Increased Safety Exe / Dual Certified ATEX - IECEx

General Information

M16 to M75 as standard.
Other thread options available on request, including BSPP, PG, NPT, ET and NPSM.

Materials & Finishes

Manufactured in Brass, Nickel Plated Brass, Aluminium, Steel, Nickel Plated Steel and Stainless Steel.

Technical Data

  1. Increased Safety and Flameproof Exe IIC Gb, Exd IIC Gb, Extb IIIC Db, ex logo II 2GD.
  2. Certificate Nos
    baseefa11ATEX0150U and IECEx BAS 11.0072U.
  3. Suitable for use in:
    Zone 1, Zone 2, Zone 21 and Zone 22.
  4. Construction and Test Standards:
    IEC/EN 60079-0, IEC/EN 60079-1 IEC/EN 60079-7 and IEC/EN 60079-31.
  5. Ingress Protection:
    IP66.
  6. Operating Temperature Range:
    -60°C to 200°C.
  7. Group I, II and III.
479 INLINE ADAPTOR SELECTION TABLE
Male Thread
Size
Thread
Pitch
Male Thread
Size
Thread
Pitch
Thread
Length
Across
Flats
Across
Corners
M16 1.5 M16 1.5 15 24 26.5
M20 1.5 M20 1.5 15 30 32.5
M25 1.5 M25 1.5 15 36 39.5
M32 1.5 M32 1.5 15 46 50.5
M40 1.5 M40 1.5 15 55 60.6
M50 1.5 M50 1.5 15 65 70.8
M63 1.5 M63 1.5 15 80 88.0
M75 1.5 M75 1.5 15 95 109.5
All dimensions in millimetres.
Note: Different thread sizes and types are permitted at each end of the adaptor, a step of one thread size is permitted between the male threads. Where different thread types / sizes are supplied, the overall dimensions of the adaptor may differ from the ones in the table

Ordering Format [ Product / Thread Size / Material / Finish ]

Example: 479 / M32 Male x 1¼" NPT Male / Brass / Nickel Plated

Always state male thread first